Production Series

[dt_divider style=”narrow”/]

 Fortus 250mc

Fortus 250mc

download-datasheet-akiradatarequest-a-quote-akiradatadetail-specifications-akiradatabuyers-guide-akiradata

[toggle title=”SPECIFICATION”]
  • Material:ABSplus-P430
  • Build envelope (XYZ):254 x 254 x 305 mm (10 x 10 x 12 in.)
  • Material delivery:One build material cartridge and one support material cartridge, each 923 cc (56.3 in3)
  • Layer thicknesses:
    • 0.013 inch (0.330 mm)
    • 0.010 inch (0.254 mm)
    • 0.007 inch (0.178 mm)
  • Support structure:Soluble
  • Available colors:Ivory, black, blue, dark grey, fluorescent yellow, nectarine, olive green, red, white, and custom colors
  • System size/weight:838 x 737 x 1143 mm (33 x 29 x 45 in.)/with crate: 186 kg (409 lbs.), without crate: 148 kg (326 lbs.)
  • Achievable accuracy:
    Parts are produced within an accuracy of ± .241 mm (± .0095 in.). (Accuracy is geometry dependent. Achievable accuracy specification derived from statistical data at 95% dimensional yield.)
  • Network communication:10/100 base T connection; Ethernet protocol
  • Operator attendance:Limited attendance required for job start and stop
  • Operating environment:Maximum room temperature of 30 C (86 F)
  • Relative humidity range:30 to 70 percent, noncondensing
  • Power requirements:110–120 VAC, 60 Hz, minimum 15A dedicated circuit; or 220–240 VAC 50/60 Hz,minimum 7A dedicated circuit.
  • Software:All Fortus Systems include Insight and Control Center job-processing and management software
[/toggle]

Fortus 360mc

Fortus 360mc

download-datasheet-akiradatarequest-a-quote-akiradatadetail-specifications-akiradatabuyers-guide-akiradata

[toggle title=”SPECIFICATION”]
  • Materials:
  • Build envelope options:
    355 x 254 x 254 mm (14 x 10 x 10 in.)
    406 x 355 x 406 mm (16 x 14 x 16 in.)
  • Material delivery options:
    • One bay each for material and support canisters
    • Two bays each for material and support canisters (with larger build envelope)
  • Layer thicknesses:
    • 0.330 mm (0.013 in.)
    • 0.254 mm (0.010 in.)
    • 0.178 mm (0.007 in.)
    • 0.127 mm (0.005 in.)
  • Support structure:Soluble or break-away for PC; soluble for ABS-M30 and PC-ABS
  • System size/weight:
    1281 x 896 x 1962 mm (50.5 x 35.5 x 77.3 in.)/with crate: 786 kg (1,511 lbs.), without crate: 593 kg (1,309 lbs.)
  • Achievable accuracy:
    Parts are produced within an accuracy of ± .127 mm (± .005 in.) or ± .0015 mm/mm (± .0015 in/in), whichever is greater. (Accuracy is geometry dependent. Achievable accuracy specification derived from statistical data at 95% dimensional yield.)
  • Network communication:10/100 base T connection; Ethernet protocolg
  • Power requirements:230 VAC, 50/60 Hz, 3 phase, 16A/phase (20 amp dedicated circuit required)

[/toggle] 

Fortus 400mc

 Fortus 400mc

download-datasheet-akiradatarequest-a-quote-akiradatadetail-specifications-akiradatabuyers-guide-akiradata

[toggle title=”SPECIFICATION”]
  • Materials:
    • ABS-ESD7
    • ABS-I
    • ABS-M30
    • ABS-M30I
    • PC
    • PC-ABS
    • PC-ISO
    • PPSE
    • ULTEM9085
  • Build envelope options:
    355 x 254 x 254 mm (14 x 10 x 10 in.)
    406 x 355 x 406 mm (16 x 14 x 16 in.)
  • Material delivery options:
    • One bay each for material and support canisters
    • Two bays each for material and support canisters (with larger build envelope)
  • Layer thicknesses:
    • 0.330 mm (0.013 in.)
    • 0.254 mm (0.010 in.)
    • 0.178 mm (0.007 in.)
    • 0.127 mm (0.005 in.)
  • Support structure:
    soluble for most materials; break-away for PC-ISO, ULTEM and PPSF; soluble or break-away for PC
  • System size/weight:
    1281 x 896 x 1962 mm (50.5 x 35.5 x 77.3 in.)/with crate: 786 kg (1,511 lbs.), without crate: 593 kg (1,309 lbs.)
  • Achievable accuracy:
    Parts are produced within an accuracy of ± .127 mm (± .005 in.) or ± .0015 mm/mm (± .0015 in/in), whichever is greater. (Accuracy is geometry dependent. Achievable accuracy specification derived from statistical data at 95% dimensional yield.)
  • Network communication:
    10/100 base T connection; Ethernet protocol
  • Power requirements:
    230 VAC, 50/60 Hz, 3 phase, 16A/phase (20 amp dedicated circuit required
  • [/toggle]

 Fortus 900mc

 Fortus 900mc

download-datasheet-akiradatarequest-a-quote-akiradatadetail-specifications-akiradatabuyers-guide-akiradata

[toggle title=”SPECIFICATION”]
  • Materials:
  • Build envelope:
    914 x 610 x 914 mm (36 x 24 x 36 in.)
  • Material delivery:
    Two bays each for material and support canisters
  • Layer thicknesses:
    • 0.330 mm (0.013 in.)
    • 0.254 mm (0.010 in.)
    • 0.178 mm (0.007 in.)
  • Support structure:
    Soluble for most materials; break-away for PC-ISO, ULTEM and PPSF; soluble or break-away for PC
  • System size/weight:
    2772 x 1683 x 2027 mm (109.1 x 66.3 x 79.8 in.)/with crate: 3287 kg (7247 lbs.), without crate: 2869 kg (6325 lbs.)
  • Achievable accuracy:
    Parts are produced within an accuracy of ± .09 mm (± .0035 in.) or ± .0015 mm/mm (± .0015 in/in), whichever is greater. (Accuracy is geometry dependent. Achievable accuracy specification derived from statistical data at 95% dimensional yield.)
  • Network communication:
    10/100 base T connection; Ethernet protocol
  • Power requirements:
    • 230VAC nominal three-phase service with 5% regulation
    • 230VAC as measured phase-to-phase; 50 Hz or 60Hz; 40 Amp circuit
    • [/toggle]